10/23/2025 | Latest, SmartDog
Release Notes V4.7-r3100

Changelog V4.7-r3100
Changes
- The granularity of electricity prices can now be configured for both grid consumption and grid feed-in.
Bug fixes
- Stock market electricity control: Settings for power reduction are now displayed correctly.
Changelog V4.7-r3099
Changes
- Deye inverters: Devices with more than 30 kW can now be read and controlled.
- Telecontrol technologies are now sorted alphabetically.
- Settings can be adjusted by clicking on the column headings.
Bug fixes
- Fixed an issue with power reduction via Modbus TCP and VDE4110.
- An existing reduction from telecontrol technology was incorrectly overwritten with 100%.
Changelog V4.7-r3097
Changes
- Reduction based on the stock market electricity price can now be configured for consecutive 15-minute intervals instead of hours.
- Global load management: The on/off switch in the GUI is now disabled by default if load management has not yet been configured.
- The program now restarts after license changes.
Bug fixes
- New grid manager hidden in the GUI, as it must not yet be used.
- RemoteIO Gecon: Fixed an issue when reading analog inputs.
Changelog V4.7-r3096
New
- Fox ESS battery integrated.
- Huawei 330KTL-H1 inverter integrated.
- PhoenixContact EMpro meter integrated, both RTU and TCP.
- CommonOut switch and control can now be operated via the portal or the app.
- Alpitronic Hypercharger charging station integrated for load management.
- During serial bus search, it is now possible to select which buses should be used.
Changes
- Stock market electricity control: Activation with at least 6 consecutive hours of negative net price is now also available for the “DE” region.
- Stock market electricity graph: Prices are now rotated by 90° and displayed with 3 decimal places.
- Stock market electricity graph: The graph can now be clicked for more accurate price data.
- Stock market electricity table: Prices are now displayed with 3 decimal places.
- Stock market electricity prices are now transmitted to the portal with 3 decimal places.
- Intillion battery via EZA and OpenLoop revised.
- Fronius Hybrid battery is now updated faster via an internal timer.
- Forecast graph: Curves can now be shown and hidden by clicking the label in the legend.
- Telecontrol analog/digital technology: Additional measured values added for output via analog signal.
- Telecontrol analog/digital technology: Switching between active power setpoint analog/digital added.
- Telecontrol N-Ergie adapted to new data point list.
- Telecontrol Homburg: Data point list adjusted.
- Optional pause interval added for Sunspec for SMA.
- Inverter configuration is now created dynamically.
- Huawei SmartLogger inverter: AC voltages are read and can be used, for example, for telecontrol technology.
- Solaredge inverter: For type “SE27.6K”, ramps cannot be set — no approval for VDE4110.
- Solarmax inverter: Texts for alarm messages expanded.
- S0 output revised.
- SmartNet expanded with hardware revision.
- Stock market electricity prices are now available in 15-minute intervals.
- Charging station and battery control adapted to the new price interval.
- Battery control: SOC forecast now also works if the battery outputs an SOC of 0%, for example FoxESS.
- Reduction based on the stock market electricity price: Number of consecutive hours can now be configured.
- Reduction based on the stock market electricity price is now also available for VDE4110 and PAVe.
- Sigenergy inverter: Active and reactive power specifications adjusted.
- Sigenergy battery: Discharge power specification adjusted, with PV prioritized.
- Unique ID added for each inverter, required for the portal database.
Bug fixes
- Phase switching of Weidmüller, Heidelberg, and Sungrow charging stations adjusted. Logic now works like Wallbe, not like Alfen.
- Luna battery now displays charged and discharged energy correctly.
- Charging stations are now switched off directly during utility blocking if they are currently charging with 3 phases, without first switching to single-phase.
- Stock market electricity configurator: Fixed issue when showing and hiding the selection for active power reduction.
- Solis inverter: Devices with 4 MPPTs, each with only one current input, are now read correctly.
- Sungrow inverter: Reactive power sign corrected.
- Huawei SmartLogger inverter: Communication fault is now processed correctly.
- Global type for reactive power is now set correctly for EZA meters at the transfer station.
- Register pairs in the Modbus server are now updated correctly for PAVe.
- CommonOut control: Fixed issue when loading the state after program restart.
- Siemens meter: Correct alarm is now displayed in case of communication fault.
- Carlo Gavazzi EM530/540 meter: Fixed sign error of active power in the EZA controller.
- Battery control: Fixed issue when calculating charging slots if set to sunset-to-sunrise.
- Fixed issue in the EZA controller with PAVe limitation.
- Program restart no longer causes unnecessary data to be stored in the PowerDB.
- Telecontrol Salzburg: Fixed issue in WebVisu.
- Telecontrol Wemag: Qualifier of Command for circuit breaker is now ignored, as it must always be a pulse.
- Global load management: Only the battery master can now be selected.
- Sigenergy battery: Fixed issue with multiple UnitIDs using the same IP address.
Changelog V4.7-r3095
Bug fixes
- Fixed issue when controlling the battery via the app.
Changelog V4.7-r3094
Changes
- Stock market electricity control activation mode adjusted. Immediate activation and §15 EAG can now be selected independently.
Changelog V4.7-r3093
New
- Goodwe inverter type GW25K-MT is now supported.
- Goodwe Hybrid inverter now supports types with 3 MPPTs.
- Charging station can now be set to “MIN + PV” via the API.
- Huawei inverter: New types added, including 330 kW devices.
- License keys can now also be removed via the portal.
- Telecontrol technology Wiener Netze GmbH integrated.
- Battery systems can now be controlled via a timer.
- Solarmax inverter: Reactive power control integrated.
- Hidden sensors added for dynamic battery control, visible only with password.
Changes
- Telecontrol N-Ergie: Emergency stop is now correctly taken into account.
- Huawei Luna battery storage now calculates charged and discharged energy from power data.
- Modbus registers for available underexcited/overexcited reactive power in VDE4110 are now limited.
- Dynamic battery system control expanded for “0–24 h” mode.
- Forecast graph now displays an error message if dynamic battery control is enabled but no electricity prices are available yet for the selected day.
- Stock market electricity control §15 EAG adjusted: Activation either immediately when the threshold is reached or when the net price is negative for at least 6 hours.
- Carlo Gavazzi EM530/EM540 meter expanded for tariff switching.
- Time stamps for battery control commands adjusted for transmission to the portal.
Bug fixes
- Fixed issue in bus search for Solaredge inverters.
- Home battery configurator: Fixed inconsistencies in the settings for stock market electricity control.
- Stock market electricity control configurator: Selection for §15 EAG was sometimes displayed even when region “DE” was selected.
- Keba charging station: Fixed issue when reading status and disabling charging.
- Meter reactive power OpenLoop overexcited was processed incorrectly.
Changelog V4.7-r3092
New
- Pixi battery integrated for data readout.
- Dynamic control of battery systems based on stock market electricity price, weather forecast, and consumption forecast.
- Telecontrol Kaiserslautern via ModbusRTU.
- License added for maximum battery charging and discharging power for battery systems fully controlled by SmartDog.
- Battery systems can now be controlled by the direct marketer.
- Forecasts for battery SOC, consumption, and control commands of dynamic battery control are transmitted to the portal.
- Charging station: Surplus charging with minimum power can now be activated via the portal.
Changes
- Adamczewski meter: Timeouts increased.
- KuWo: One output if all charging stations are off, one output if at least one charging station is on.
- Reactive power control of Q(U) characteristic curve TOR Austria is transmitted to slaves via Modbus.
- Modbus server: Reactive power setpoint in the EZA controller now accepts all values, but limits them to the valid range.
- Telecontrol Energie AG: Measured values for storage systems added.
- Sofar inverter: Active and reactive power specifications are now sent using broadcast commands.
- Telecontrol analog/digital technology expanded with fault messages.
- Stock market electricity control expanded with §15 EAG, only for Austria.
- Charging station widget: Mode settings, such as surplus, immediate with maximum power, forced charging, etc., are now displayed like in other widgets — centered, full screen, with greyed-out background.
- Static control of battery systems based on stock market electricity price: Forced charging now takes place during the cheapest times up to the configured SOC, regardless of the actual price.
- Solaredge inverter: Active and reactive power control adjusted for EZA controller and TOR Austria.
Bug fixes
- Zoe battery: Values are now reset in case of communication fault.
- Consumption forecast: Recalculation is now only performed at midnight.
- Meter reading is now correctly transmitted in EZA master-slave systems with WAGO meters.
- Kostal inverter: Active power gradient is now correctly set in the EZA controller in OpenLoop mode.
- Battery control now works in combination with the priority list.
- Reduction based on stock market electricity is now correctly updated when the validity of external release changes.
- Stock market electricity control: Fixed loading issue.
- Huawei battery: Fixed limitation of charging and discharging power. Display issue only, no control issue.
- Classic heat pump widget can now be deleted as expected.
- Detailed heat pump widget: Overview is now displayed in the foreground above all widgets.
- Global load management: Fixed incorrect phase assignment of single-phase charging stations.
- Global load management: Setpoint value for battery power is now determined correctly.
- Solax inverter: Active and reactive power control now works.
Changelog V4.6-r3091
New
- Zevvy portal, available with license.
- Control of Sungrow Hybrid battery.
- Control of Pramac battery.
- Control of Fronius Hybrid battery.
- Control of Deye battery, only with stock market electricity.
- Control of ZOE battery.
- Visualization and control of Sigenergy hybrid system.
- Deye inverter: Switching of generator connection during grid failure and grid return.
- Telecontrol WEMAG: Data point list of municipal utilities.
- Telecontrol Kiendler Vulkanland.
- Telecontrol Ulm.
- Telecontrol N-ERGIE.
- Consumption forecast.
- 5-minute values of calculated meters can now be recalculated retrospectively.
- Load limitation and reduction according to §14a EnWG.
- Weather forecast and stock market electricity price data are now transmitted to the portal in advance.
- Sungrow charging station for surplus charging with phase switching and load management.
- Surplus charging of charging stations expanded for charging with minimum power.
Changes
- IEC60870 library updated from V2.3.1 to V2.3.3.
- Weather forecast revised.
- Calculation of theoretically available active power revised.
- Calculation of energy from calculated UEST and PV meters adjusted.
- VPN server changed to “vpn.smart-dog.eu”.
- Fixed active power reduction in the grid manager is now available again with telecontrol technology.
- Telecontrol Energie AG expanded for controlling battery storage systems.
- Telecontrol analog/digital technology expanded.
- Telecontrol configurator: Outputs can no longer be assigned twice.
- System settings revised and option added to enable or disable weather forecast.
- General legionella protection now works identically to legionella protection via the MyPV menu. Controls must be recreated; existing configurations remain unchanged.
Bug fixes
- Improved resolution of hostnames to IP addresses.
- RemoteIOs now show the correct number of inputs and outputs again.
- Fronius battery: Battery control is now correctly disabled again.
- Serial meters in EZA systems can now be created as expected.
- PID settings for battery control are only displayed on the master.
- Reactive power sign adjusted for SMA Data Manager.
- Reactive power control TOR Austria: Fixed issue in formula.
- Grid manager hidden again for EZA.
- Graphs for meters, sensors, and weather forecast now update automatically.
- Solis inverter: Serial number is now displayed correctly.
- Fixed issue in data transmission to the portal for Meteocontrol.
Changelog V4.6-r3089
Bug fixes
- Curves for meters are displayed correctly again when no sensors have been created.
- Buttons in info popups are displayed correctly again.
Changelog V4.6-r3088
Changes
- Settings menu is now closed after 2 hours of inactivity between 00:00 and 02:00.
- Growatt inverter: Alarm for error number 0 disabled.
Bug fixes
- Fixed issue when saving UnitIDs of charging stations.
- Charging station widget: Settings work again.
- Fronius RS422 inverter: Data is now checked more thoroughly for validity.
- Curves for meters are now hidden correctly again when the selection is changed.
Changelog V4.6-r3086
New
- External release for battery charging with stock market electricity added.
- SMA STP6.0-3SE-40 battery can now be read.
Changes
- Network settings can now also be saved without an internet connection.
Changelog V4.6-r3085
New
- Huawei battery can now be controlled via the battery widget and based on the stock market electricity price.
- Battery control now offers master-slave functionality.
Changelog V4.0-r3077
New
- Telecontrol Dortmunder Netz integrated.
- Telecontrol Netz Niederösterreich integrated.
- Formula for calculated meters and controls is now easier to edit.
- Gross price of the stock market electricity price can now be calculated and used for controls.
- Standard formulas for the providers tado, formerly aWATTar, and Tibber added.
- These formulas can be easily adjusted, for example due to regional price differences.
Bug fixes
- Calculated meters in EZA systems now show the correct energy values, including own consumption and total consumption.
- Values from 1-Wire meters and sensors are now checked more thoroughly for plausibility.
- Value overflow for feed-in and consumption meters of Deye inverters fixed.
Changelog V4.0-r3074
New
- Heidelberg EnergyControl and Connect charging stations integrated for surplus charging and load management.
- Settings menu now closes automatically without saving after too much inactivity.
- AlphaESS battery storage integrated for control by stock market electricity and discharge blocking during one-time full charging of a charging station.
- Inverters no longer need to be selected for power reductions, as all inverters are now reduced by default.
- Load management now includes an additional selection for utility reduction according to §14a EnWG of the Federal Network Agency.
- Alarms for power/yield deviation and string/module field failure are now only displayed for Kaco and SMA at 100% power specification, as the strings are not reduced evenly in this case.
- Automatically created meters now display the calculation formula and can no longer be edited, as otherwise the calculation would no longer work.
Bug fixes
- Energie AG meter now records meter readings for active and reactive energy correctly.
- Wizard for hybrid systems now correctly creates meters for consumption and feed-in for Fronius.
Changelog V4.0-r3057
New
- System custom view displays outside temperature.
- Stock market electricity now also available for charging stations.
- Stock market electricity now also available for heating rods.
- Telecontrol simulator displays IOA.
- EZA widget expanded with meter data.
- Weather forecast integrated.
- Master/slave system for VDE4110 systems.
Bug fixes
- VDE4110 adjustments to the current certified version.
- Reactive power curves Q(U) and cosPhi(U): Individual value pairs of the curve were saved incorrectly.
- Priority activation issue fixed.
- Heat pump issue fixed.
Changelog V4.0-r3056
New
- Sofar bug fix.
- SMA Core2 bug fix.
- Solis cosPhi control bug fix.
- Weidmüller AC Smart bug fix.
Bug fixes
- Solis inverter expanded to up to 24 strings.
- Sungrow logger integrated.
- Selec MFM384-RC meter, E-Werke Wels, integrated.
- Stock market electricity control, inverter curtailment, integrated.
- Automatic creation of meters for PV generation, own consumption, and total consumption.
Changelog V4.0-r3054
Bug fixes
- Test inverters were found during Sunspec inverter network search.
- Telecontrol Tiroler Netze byte order adjusted.
- Bus search via network improved. 10 manufacturers can now be created.
- Power reduction integrated for VDE4105 systems.
- Timeout for Fronius at 9600 baud increased.
- Sunny Tripower X calculated reactive power incorrectly.
New
- Solax data logger integrated.
- Telecontrol Westnetz for 100 kW < P < 135 kW, VDE 4105.
- Inverters can now be deleted easily.
- Senec can only be read via HTTPS in newer firmware versions. Older versions, however, only via HTTP. Function for detection integrated.
- Active and reactive power control for Sunny Tripower X.
More news